Carlin Combustion  

North Haven,  CT 
United States
https://carlincombustion.com/


Thank you for stopping by our Booth! Send us a message!


Carlin Combustion Technology burns more than just the midnight oil.

Over the years, we've fine tuned our desgins to bring you the best in oil, natural gas and propane burners, as well as ignitors, controls and related components such as motors, oil valves, circuit interfaces and burner cover kits, for both residential and commercial applications.


Customer Service YOU Deserve

We pride ourselves on giving each call and e-mail we recieve with the upmost attention and priority. Wheter your placing an order, inquiring where to buy, looking for parts, or have a technical question at 4:30 on a Friday, we can guarentee that YOU will come first. Please reach out, we'd love to hear from you!

Customer Service:

203-680-9401

sales@carlincombustion.com

Technical Support

1-800-989-2275

mwarn@ccowles.com


Unviersal Replacements!

Perfect for Any Job! With our universal product line, you never need to worry about having the correct primary control, boiler control or ignitor because each of our universal products fits multiple brands. Stocking your truck with Carlin and Hydrolevel’s universal product line will give you the peace of mind of having everything you need on your truck to get the job done right. Featuring 

Pro-X 70200 Universal Oil Primary

Pro-X 45000 Unviersal Oil ignitor

Hydrolevel's Fuel Smart Hydrostat Universal Boiler Control


Burners for any Job!

Whether it be residential, commerical, oil, or gas, we have the burner you've been looking for. Individually tested and outfitted with the latest technology and components, each burner gets the stamp approval from our shop and ships spec'd out for your appliance!

Residential Burners!

Commerical Oil Burners

Comemrical Gas Burners


 Videos

Pro X 70200 - Status Icons & Screen Messages
Carlin 48245 Control
Carlin Pro X 45000 Universal Ignitor

 Products

  • CAP System
    Provides direct combustion air & shuts down the burner in the event the outside combustion air supply becomes blocked....

  • The Carlin CAP (Combustion Air Proving) System — A Superior Solution for Meeting Combustion Air Code Requirements.

    • Easily Installed
     Building Code Compliant*
    • Preferred by Homeowners

    Why fill a homeowner’s basement with cold air in the winter and humid air in the summer? When dealing with combustion air or confined space limitations, the CAP System is a superior solution!

    By providing direct combustion air to your appliance and allowing you to reduce the area considered “confined” for ventilation by 50%, the CAP System makes dealing with confined space installations a breeze!

    The Carlin CAP System provides code compliant piece of mind!

    *Designed to meet NFPA31, section 5.4.3.3, as covered by April 2019 TIA 16-2

    Patent Pending

    Why CAP System –Smart Technology for Efficiency and Safety!

    No More Space Limitations
    The CAP System’s patent pending design safely provides DIRECT COMBUSTION AIR to your appliance, allowing you to reduce the area considered “confined” for ventilation by up to 50%!

    Code Compliance Just Got Easier
    Designed to comply with NFPA 31* requirements for supplying combustion air in confined spaces, the CAP System includes safeguards that shut down burner operation in the event of blockage of the air passage to the oil burner(s)!
    * Designed to meet NFPA31, section 5.4.3.3, as covered by April 2019 TIA 16-2.

    Homeowner Satisfaction, the Win-Win
    Efficient, effective and easy. Instead of spending hours installing other devices that flood cold or hot humid air into the home and run up the homeowner’s electric bill, go with the CAP System! It’s simple to install, requires no additional power for operation and adds to the ALREADY quiet operation of a Carlin Burner.

    How it works
    The CAP system runs a combustion air intake
    test during each Pre-Purge. If there is no blockage, your appliance will proceed with its standard operation. If it senses an air block, the CAP System works with our
    Pro-X 70200 Oil Primary to abort ignition and shut down the burner, giving you a chance to check out the problem. The CAP System continually monitors your combustion air intake, so even if the burner runs, THEN experiences a blockage, the CAP System will communicate to the burner to cease operation!


    Resources

    Webpage

    Installation Manual

    Features and Benifits

  • Pro-X 70200 Universal Oil Primary
    The Brains of our Burner, featuring Universal Mounting, on board diagnostics, and so much more!...

  • The Busy Tech's Best Friend! 

    The Pro-X 702000 is desgined to be the only primary controly you'll ever need thanks to it's Unviersal Moutning and adjustable settings! 

    Features and Specs!

    • Universal Mounting - Replaces virtually any oil primary control
    • On-Board Diagnostics - Pinpoints cause of burner faults for fast, accurate repairs
    • Ignition Efficiency - 3 different ignition options available (Smart, Interrupted and Intermittent)
    • Last Fault Alert – Displays reason for last fault, even if homeowner resets control
    • Fault History – keeps on-board record of the last 32 cycles
    • Larger LCD Display – Shows straightforward fault messages with no codes to decipher
    • Simple Setup – “Plug and Play” on your favorite application
    • Recessed Wiring Terminals – Added wiring space in j-box
    • Low Voltage Blocked Vent Contacts – Allows for easy connections

    Power input (red/white wire): 120 VAC, 60 HZ, 9 VA

    Limit circuit input (black wire): 120 VAC, 60 HZ

    Motor load (orange wire): 10 FLA / 60 LRA (reduce by valve load)

    Ignitor load (blue wire): 120 VAC, 60 HZ, 500 VA

    Valve load (violet wire): 120 VAC, 60 HZ, 2A

    Vent load:  0.1 amp

    Line heater:  1 amp

    Alarm contacts (dry contacts): 24V, AC/DC, 2A

    Operating temperature limits: +32°F to +140°F

    Storage temperature limits:  -40°F to +185°F

    Thermostat anticipator current: 0.1 A, AC

    Agencies: UL recognized (US & Canada


    Resources

    Webpage

    Installation Manual

    Features and Benifits

  • EZ-Series Residential Oil Burner
    Our Premier Residential Oil Burner!...

  • Desgined with the Tech in Mind!


    What can the Carlin EZ-Series offer you? 

    Quiet Operation

    • Unique blower design nearly eliminates fan noise

    • Combustion and ignition noise virtually eliminated by the unique nose cone design

    Electronic Reliability

    • Comes standard with time-tested solid state ignition and state-of-the-art microprocessor control technology

    Carlin Pro-X 70200 Universal Oil Primary Control: Featuring Last Fault Alert, Detailed Fault History, simple navigation buttons with LCD Display, & more!

    Carlin Pro-X 45000 Universal Ignitor: Engineered and tested for unquestionable durability

    Unmatched Performance

    • EZ Burner design yields exceptional fuel/air mixing for wide range of operation

    • 5, 7, 9 or 11-inch air tube and combustion head, with 18 SR stainless steel nose cone

    • Oil pump with secondary internal cone valve provides added shut-off protection

    • OEM Specified – Manufactured to OEM specifications to optimize appliance efficiency and performance

    • High quality PSC Motor provides required torque while reducing energy consumption


    SPECIFICATIONS

    Input:

                  EZ-1: 0.50 - 1.65

                  EZ-2: 1.50-2.25

                  EZ-3: 2.00-2.65

    Fuels:

    U.S. – No. 1 or No. 2 Fuel Oil

    Canada – No. 1 Stove oil or No. 2 Furnace oil

    Electrical Power:

    Power: 120 vac/60 hz/1-phase

    Current – Approximately 5.8 amps

    Limit circuit input – 120 vac/60 hz

    Motor (PSC) – 1/6 hp, 3450 rpm

    Oil valve power – 120 vac/60 hz

    Nozzle line heater – 120 vac/60 hz

    Alarm contacts (isolated) – 24 vac/vdc, 2 amps

    Ignition:

    Carlin Model 45000 solid state electronic ignitor

    Ignition voltage – 14,000 volts

    Primary Control:

    Carlin Model 70200 microprocessor control

    • 15-sec. Trial for ignition (TFI)

    • Pump prime

    • Serviceman reset protection (Latch-up after three consective lockouts)

    • Interrupted duty ignition

    • Recycle on flame failure

    Operating Temperature Limits:

     Maximum ambient – 140°F (60°C)

    Agencies

    UL Listed (US & Canada)


    Resources!

    Webpage

    Installation Manual

    Features and Benifits

  • 48245 Oil Primary Control
    A simple, cost effective replacement for your current 3-wire oil primary OR add a wire, and activate the Smart Ignition feature!...

  • Get the best of both worlds with the 48245 Oil Primary! 

    ✓ Comes configured for easy wire-for-wire replacement of any 3-wire control!

    ✓ Additional ignitor wire included to activate Smart Ignition feature!


    Like any 3-wire control, the 48245 comes configured for easy wire-for-wire replacement of any 3-wire control, (including the Honeywell R8184G).

    You can wire it up like any 3-wire control and be done – or use the additional blue/ignitor wire in the box which, when connected, will automatically activate the control’s Smart Ignition features. When Smart Ignition is activated, the 48245 runs the ignitor in Interrupted Duty whenever possible to dramatically extend the life of the ignitor/transformer and electrodes. Smart Ignition automatically switches to Intermittent Duty (often called “constant duty”) when needed to ensure flame retention and eliminate unnecessary service calls. In a typical home, Smart Ignition can reduce the ignitor run time from 1,000 hours to under 50 hours per year. 


    Specs

    Power Input (From Limit Circuit): 120vac, 60 Hz, 10 VA

    Motor Load: 5 FLA/60 LRA

    Ignitor Load: 120 vac, 60 Hz, 500 VA

    Operating Temperature Limits: +32°F to + 140°F

    Storage Temperature Limits: -40°F to +185°F

    Thermostat Anticipator Current: 0.1 A, AC

    Agencies: UL & ULC Recognized Component United States & Canada


    Resources

    Webpage

    Installation Manual

    Features and Benifits

  • EZGas Pro Conversion Burner
    Our Premier Residential Gas Burner!...

  • The Carlin EZGas Pro conversion burner is designed to convert oil-fired appliances to natural gas or propane.

    When the existing oil appliance is in good operating condition, the EZGas Pro burner is fast and easy to install and provides a significantly less expensive alternative to replacing the heating appliance!


    Burner Specs and Features!

    Input

    50,000 to 275,000 BTUH

    Fuels

    Natural gas or propane gas

    Maximum supply pressure.........

    14 inches w.c. Minimum supply pressure

    5.0 inches w.c. Manifold pressure

    3.5 inches w.c.

    Electrical

    Power.......................................... 120 VAC/60 Hz/1-phase

    Limit circuit input....................... 120 VAC/60 Hz

    Motor.......................................... 1/15 HP, 3450 RPM

    Current........................................ Approximately 2.0 Amps

    Fuel valve power........................ 24 VAC

    Ignition

    Carlin Model 41800 solid state electronic ignitor

    Ignition voltage.......................... 9,000 Volts

    Control

    Carlin Model 60200FR microprocessor control

    Agencies

    UL Listed (United States)........... per ANSI Z21.17

    MEA approval............................. #137-05-E

    • Compact flame pattern ensures clean, quiet operation
    • Easy color-coded wiring
    • Durable spark ignition with flame rod rectification
    • Operates in low and fluctuating gas pressures
    • Mixes fuel inside the combustion chamber for safe reliable operation
    • Advanced 60200FR Primary Control
      • LCD screen displays burner status as well as fault messages.
      • On-screen micro amp readings.
      • Built-in diagnostics to identify component failures.
      • Stores detailed fault history up to 50 fault cycles, taking the guess work out of servicing.
      • Features easy, on board programming.
      • Other features include Blocked Vent Input, Alarm Contacts and more!

    Resources

    Webpage

    Installation Manual

    Sales Sheet

  • NEW Commercial Burner Offering!
    New for 2020, we will be rolling out 4 new commercial burners!
    The Dual Fuel 801G/O and 702G/O & The Gas fired 801GAS and 702GAS!...

  • We are expanding our Commerical Burner line-up with 4 new players for 2020;

    The Dual Fuel 801G/O & 702G/O, as well as the Gas Fired 801GAS and 702GAS! Following the Carlin tradtion, each burner is built the techcnician in mind, sporting a rugged desgin along with the latest components and technology to make your install and troubleshooting a breeze!

    Contact our factory for ordering information!

    Sales@carlincombustion.com

    203-680-9401


    Features!

    Multiple Firing -Large selection to suit your job

    Upgraded Panel Desgin - Easy to navigate wiring along with LED indicators and switches for streamlined firing/ troubleshooting

    Direck Spark Ignition

    120V Control System - Honeywell and Fireye options available

    NEW Prewired Gas Trains - Specifically desgined to support the new burners (sold seperately) 


    SPECS!

    801GAS

    Gas Input:

    High fire: 1,400 to 2,500 MBH

    Low fire: 810 to 1,400 MBH

    Fuels:

    Natural gas or propane

    Gas train: (available in straight or angled configuration)

    (2) Main gas valves & RV-81 regulator

    Butterfly gas valve for input regulation

    11⁄2" gas train standard; 2" gas train available

    Electrical

    Power: 120 vac/60 hz/1-phase

    Limit circuit input: 120 vac/60 hz

    Control circuit load (120 vac): 1.2 amps

    Motor:  4 hp, 3450 rpm, 56C-frame

               115 / 208-230 vac/60 hz/1-ph, 9.8 / 4.8-4.9 amps

                Opt: 208-230 / 460 vac/60 hz/3-ph, 3.0-3.2 / 1.6 amps

    Damper motor (with end switch): Siemens SQN71

    Ignition:

    Carlin solid state 41800 ignitor

     Ignition voltage: 9,000 volts

    Primary control

    Honeywell RM7897C or Fireye MEC120

    Agencies

    UL Listed (US)

    702GAS

    Gas Input

    High fire: 840 to 1,600 MBH

    Low fire: 490 to 940 MBH

    Fuels

    Natural gas or propane

    Gas Train (available in straight or angled configuration)

    (2) Main gas valves & RV-61 or RV-81 regulator

    Butterfly gas valve for input regulation

    1" gas train standard; 1¼", 1½" or 2" gas train available

    Electrical

    Power 120V/60 Hz/1-Phase

    Limit circuit input (RM7895C or RM7897C) 120 vac/60 hz

    Control circuit load (120 vac) 1.2 amps

    Motor 1/2 hp, 3450 rpm, 48-frame, “N” flange 115 / 208-230 vac/60 hz/1-ph, 8.4 / 3.8-4.2 amps

    Gas valve power 120 vac/60 hz

    Damper motor Siemens SQN71

    Ignition & Primary Control

    Carlin Model 41800 solid state electronic ignitor

    Ignition voltage 9,000 volts

    Primary control Honeywell RM7897C

    Agencies

    UL Listed (US)

    801G/O 

    Oil Input

    High fire: 10.4 to 17.5 GPH

    Low fire: 6.6 to 7.9 GPH

    Gas Input

    High fire: 1,200 to 2,500 MBH

    Low fire: 810 to 1,400 MBH

    Fuels

    No. 1 or No. 2 Fuel oil

    Natural gas or propane

    Fuel unit & oil valves:

    Fuel unit, 2-stage, 150 psig

                    (2) Oil solenoid valves

    Gas train: (available in straight or angled configuration)

    2) Main gas valves & RV-81 regulator

    Butterfly gas valve for input regulation

    11⁄2" gas train standard; 2" gas train available

    Electrical

    Power: 120 vac/60 hz/1-phase

    Limit circuit input: 120 vac/60 hz

    Control circuit load (120 vac): .2 amps

    Motor:.3/4 hp, 3450 rpm, 56C-frame

               115 / 208-230 vac/60 hz/1-ph, 9.8 / 4.8-4.9 amps

               Opt: 208-230 / 460 vac/60 hz/3-ph, 3.0-3.2 / 1.6 amps

    Oil valve power:  120 vac/60 hz

    Damper motor (with end switch):  Siemens SQN71

    Ignition

    Gas: Carlin Model 41800 Solid State Ignitor

    Ignition Voltage: .9000 volts

    Oil: Carlin Model 45000 solid state ignitor

    Ignition Voltage: 14000 volts

    Primary control

    Honeywell RM7897C or Fireye MEC120

    Agencies: UL Listed (US)

    702G/O

    Oil Input

    High fire: 6.0 to 11.2 GPH

    Low fire: 3.5 to 6.5 GPH

    Gas Input

    High fire: 840 to 1,600 MBH

    Low fire: 490 to 940 MBH

    Fuels

    No. 1 or No. 2 Fuel oil Natural gas or propane

    Fuel Unit & Oil Valves

    Fuel unit, 2-stage, 300 psig (with internal blocking valve)

    (2) Oil solenoid valves

    Gas Train (available in straight or angled configuration)

    (2) Main gas valves & RV-61 or RV-81 regulator

    Butterfly gas valve for input regulation

    1" gas train standard; 1¼", 1½" or 2" gas train available

    Electrical

    Power 120V/60 Hz/1-Phase

    Limit circuit input (RM7895C or RM7897C) 120 vac/60 hz

    Control circuit load (120 vac) 1.2 amps

    Motor 1/2 hp, 3450 rpm, 48-frame, “N” flange 115 / 208-230 vac/60 hz/1-ph, 8.4 / 3.8-4.2 amps

    Oil valve/gas valve power 120 vac/60 hz

    Damper motor Siemens SQN71

    Ignition &

    Oil:  Carlin Model 45000 electronic ignitor, 14,000 volts

    Gas: Carlin Model 41800 electronic ignitor, 9,000 volts

    Primary Control

    Honeywell RM7897C or Fireye MEC120

    Agencies

    UL Listed (US)

  • Commercial Oil Burners
    Featuring the 201/301CRD, 601CRD, 701/801CRD, 702CRD, 1050/1150FFD!...

  • Combining high performance, easy servicing and a quality build, Carlin has the burners to fit your commerical oil needs!

    Featuring our Pro-X 70200, standard on all comemrical oil burners!


    Burner Inputs and Features!

    201CRD/ 301CRD

    201CRD: 2.5 to 5.5 GPH

    301CRD: 3 1/4” air cone, “B” style: 3.0 to 6.0 GPH

                     3 ½” air cone, “C” style: 4.0 to 7.0 GPH

    • Adjustable combustion head for unmatched fuel/ air mixing, smooth light-offs, and quiet operation
    • Simple and easy installation on OEM boilers.
    • Easy setup and servicing: Only adjustments required are to the air band and the combustion head, set with Carlin’s easy-access screw adjustment.
    • Positive ignition, stable operation and compact flame.
    • 301CRD burner is available in two firing ranges, depending on air cone diameter selected

    601CRD/ 701CRD/ 702CRD/801CRD

    601CRD: 6.0 to 13.2 GPH

    701CRD: High Fire: 6.0 to 13.2

                     Low Fire: 3.6 to 6.6

    702CRD: High Fire: 6.0 to 13.2

                     Low Fire: 3.5 to 7.5

    801CRD: High Fire: 11.4 to 19.8

                     Low Fire: 6.6 to 8.4

    • Automatically closed air damper w/ low-high-low step modulation improves efficiency by effectively matching output to demand and reducing standby losses
    • Equipped with Carlin’s adjustable combustion head assembly for unmatched fuel/air mixing, smooth light offs and quiet operation. 
    • Easy servicing: Only adjustments required are to the air shutter and combustion head.
    • Blower access cover allows full view of blower compartment.
    • Jacob’s-ladder electrode tips for wide spark pattern and reliable ignition.

    1050FFD/ 1150FFD

    1050FFD: High Fire: 15.0 to 25.0 GPH

                      Low Fire: 9.0 to 12.0

    1150FFD: High Fire: 20.0 to 35.0

                      Low Fire: 12.0 to 15.0

    • Carlin’s exclusive Flame-Funnel Combustion.
    • Automatically closing air damper & low-high-low step modulation to improve efficiency by effectively matching output to demand and reducing standby losses.
    • Easy servicing: Only adjustments required are to the air shutter and the combustion head, set with Carlin’s easy-access screw adjustment.
    • Each burner (1050 or 1150) uses a single set of air handling parts for all firing rates. All burners use Carlin electronic ignitors.
    • Excellent performance when tested in appliances that do not use refractory combustion chambers.

    Resources

    201/301CRD Webpage

    601CRD Webpage

    701/801CRD Webpage

    702CRD Webpage

    1050/1150 FFD Webpage

  • Commercial Gas Burners
    Featuring the 201GAS, 301GAS, and 601GAS!...

  • Proven for years in the field and in extensive boiler and furnace testing, these burners will meet your needs for commercial gas-burning applications.

    Comes standard with time-tested solid state ignition and state of the art microprocessor primary control technology.

    Factory-packaged with combustion control and fully assembled gas train.


    Input and Features!

    201GAS

    "B" Style Head/ Tube: 2150,000 to 300,000 GPH

    "C" Style Head/ Tube: 300,000 to 399,000 GPH

    • Converts from propane to natural gas with just an orifice change. No conversion kit needed!
    • Provides dependable, direct spark ignition of main flame for quick, clean light-offs.
    • High efficiency, compact flame pattern design ensures clean, quiet operation.
    • Shipped completely pre-wired for easy installation and startup. Knockdown version also available.

    301GAS/ 601GAS

    301GAS “B” Style Head/ Tube: 401,000 to 700,000 GPH

    301GAS “C” Style Head/ Tube: 550,000 to 1,100,000

    601GAS “11/B” Style Head/ Tube: 700,000 to 1,000,000

    601GAS “21/C” Style Head/ Tube: 800,000 to 1,050,000

    601GAS “32/D” Style Head/ Tube: 900,000 to 1,500,000

    • Converts from propane to natural gas with just an orifice change. No conversion kit needed!
    • Factory-packaged with combustion control and gas train (assembled, shipped loose; also available as knockdown.
    • Shipped completely pre-wired for easy installation and startup. Knockdown version also available.
    • Does not require a refractory liner. Fires with or without a combustion chamber.
    • Swing-away housing design.
    • Available with custom welded air tube flange (and/or optional pedestal) to accommodate most appliance mounting requirements.


    Resources

    201GAS Webpage

    301GAS Webpage

    601GAS Webpage

  • Pro-X 45000 Universal Oil Ignitor!
    Our Universal Oil Ignitor!...

  • The Last Ignitor you'll ever need! 

    The Pro-X 45000 is simply Carlin’s most durable ignitor ever. In our most rigorous testing, under extreme conditions the Pro-X 45000 outlasted every ignitor we’ve ever tested… and we have tested them all. But long life is only half the story… The Pro-X 45000 is also Universal. The rugged thermoplastic housing features mounting locations for virtually any burner, so no matter the burner you are servicing you’ll have the right ignitor for the job when you arrive.


    Features and Specs!

    • Universal Mounting for virtually and existing manufactures base plate
    • Robust Circuit Design
    • Stronger Components
    • Optimized Heat Management

    Power Input: 120 VAC, 60 HZ, 40 VA

    Ignitor Output: 19 KV, 35 mA RMS

    Secondary Grounding: Midpoint

    Operating Temperature Limits: +32°F to +140°F

    Storage Temperature Limits: -40F to +185°F

    Agencies: UL Recognized U.S. and Canada


    Resources!

    Installation Manual

    Sales Sheet

    Webpage

  • EZ-Temp
    Our Microprocessor Temperature Control!...

  • The EZ-Temp temperature control brings together a proven, durable, easy to install design and intuitive, user friendly interface to make it the premier temperature control on the market!


    Burner Specs and Features!

    • Dynamic Display shows temperature setting and error codes. 
    • Navigation buttons allow for easy transition of EZ-Temp modes and settings. 
    • LEDs to indicate Lockout/Latchup and Call for Heat. 
    • Individual, dual and triple sensor options 
    • Smart Manual Reset allows for manual reset only if operating limit doesn’t open

    DISPLAY MODELS 90000B 90000C 90000CE 90200A 90200G 90300B 90320B
    Control Power Input 120VAC, 11VA 120VAC, 11VA 120VAC, 11VA 120VAC, 11VA 120VAC, 11VA 120VAC, 11VA 240VAC, 50/60 hz,
    12VA
    Adjustable Operating Limit Range 50°F to 240°F 50°F to 240°F 50°F to 240°F 50°F to 240°F 50°F to 240°F 50°F to 240°F 50°F to 240°F
    Fixed High Limit Temperature* 100°F to 240°F 100°F to 240°F 100°F to 250°F 160°F to 240°F 160°F to 240°F
    Fixed Differential (subtractive)* 5°F to 100°F 5°F to 100°F 5°F to 100°F 5°F to 100°F 5°F to 100°F 5°F to 100°F 5°F to 100°F
    Operating Temperature Limtis 32°F to 140°F 32°F to 140°F 32°F to 140°F 32°F to 140°F 32°F to 140°F 32°F to 140°F 32°F to 140°F
    Storage Temperature Limits -40°F to +185°F -40°F to +185°F -40°F to +185°F -40°F to +185°F -40°F to +185°F -40°F to +185°F -40°F to +185°F
    Agencies UL Recognized (United States & Canada)

    DIAL  MODEL 90224A
    Control Power Input 24VAC, 1VA
    Adjustable Operating Limit Range 50°F to 240°F
    Fixed Differential (subtractive) 5°F to 100°F
    Operating Temperature Limtis 32°F to 140°F
    Storage Temperature Limits -40°F to +185°F
    Agencies UL Recognized (United States & Canada)


    Resources

    Model 90000 Web Page

    Model 90200 Web Page

    Model 90300 Web Page

    Model 90320 Web Page

    Model 90224A (Dial) Web Page

For Technical Support with this webpage, please contact support.