WC&P International – Providing Change with Water
WC&P, May 2024 – Not many companies can take pride in their origin in humanitarian efforts to address resource scarcity, but HANS Premium Water can.
Modular, intelligent water systems that save water, reduce costs and eliminate downtime
Water solutions that protect assets, reduce maintenance, and eliminate the need for bottled water.
Water solutions that provide consistent, predictable water quality.
HANS® has reinvented every component used to treat water – from the redundant pump to reverse osmosis elements into intelligent, efficient, space-saving devices. They are designed to work together in modular, scalable systems to meet every need. So even if your customers have brackish water, or need de-ionized water, or use a million gallons per day, HANS components can be assembled to get the job done – quickly, easily and effectively.
With the HANS Quad RO, your customers can realize a recovery rate of up to 95%. That means far less wasted water, and wasted money, than other systems.
First and only high capacity RO system 3rd party certified for removal of contaminates to EPA standards*
All HANS water solutions are Wi-Fi compatible and provide the data your business needs – like water usage, pressure, TDS levels and filter life. All this data is on each module’s data screen, and it’s delivered in real time to a mobile device.
HANS systems can operate in two modes:
Mode 1: Flow Maintenance
System sensors adjust the variable-speed pumps as needed to keep up with a set flow rate (volume) rather than running at full speed only, thus saving energy. It’s ideal for facilities using a storage tank.
Mode 2: Pressure Maintenance
System sensors automatically adjust flow, as needed, to keep outlet pressure at a set value. It’s ideal for facilities that require water on demand rather than a storage tank.
HANS uses only variable-speed DC motors controlled by sensors that detect water conditions. Motors run only as much as they have to, saving energy.
With HANS, your water system can change and grow as your business changes and grows. Need more output? Add more modules. Need more pressure? Add a pump module. Need cleaner water? Add more treatment modules.
HANS modules also give you redundancy and easy maintenance. If one treatment module needs maintenance, the unit is simply bypassed, taken offline, serviced, then re-attached. No need to shut down the water system.
*Certified by IAPMO R&T to LEC 2006
*Input levels outside of device parameters may require pretreatment such as a water softener or iron breaker.
WC&P, May 2024 – Not many companies can take pride in their origin in humanitarian efforts to address resource scarcity, but HANS Premium Water can.
HANS Climate is a micro-site that explores solutions to climate change and clean water for the world. Learn more about the back story of HANS Premium Water and how the founder is looking for solutions.
This article details Hans Premium Water use in indoor farming. The interview is with Rick Cunningham, Chief Commercial Officer of Hans Premium Water.
Detroit Business March-April 2024 Issue spotlights Manoj Bhargava,
Lead is commonly found in school and childcare center drinking water across the country, including in Michigan because most plumbing materials contain lead that leaches into drinking water, even with new faucets and fixtures marked “lead free.”
Michigan will be the first state in the nation to require filtered drinking water at all schools and daycare centers under new laws signed Thursday by Democratic Gov. Gretchen Whitmer. Facilities will have until the end of the 2025-26 school year to install at least one bottle-filling station or faucet…
Water scarcity and access to clean water are two of the most important topics facing the world today. As part of our commitment to sustainable water, HANS Premium Water provides businesses with access to premium treated water while minimizing water use and water waste thus helping their efforts to conserve…
Hard water is the bane of food and beverage manufacturers. Scale deposits cause equipment to break at unpredictable times, resulting in downtime and the need to cobble together components from different makers.
Sign up to get the latest product information and tips delivered straight to your inbox.
Use the form below to get in touch with us or call us at 833-333-4267. We’re here to help.
*required fields
We currently do not have any dealers in your area at this time. Contact us today so that we can help find a dealer for you!
Private well owners are responsible for the safety of their water. The Environmental Protection Agency does not regulate or enforce legal limits of contaminants found in private wells. It is up to the well owner to test and treat for these contaminants to ensure the safety and wellbeing of those using water from that source. Along with the common complaints amongst private well owners regarding the taste, smell, and appearance of their well water, that water could also contain levels of contaminants such as radioactive substances, metals or fluoride, agricultural chemicals, fertilizers, pesticides, and the list goes on. The U.S. Geological Survey released a report in 2009 finding that almost one-fourth of private domestic wells contain levels of these potentially harmful contaminants.
According to the Environmental Working Group, Substances found in groundwater and surrounding mineral deposits include:
When should I have my water tested?
The Centers for Disease Control and Prevention recommend regular mechanical maintenance & testing your well every spring. Regular testing is recommended because contaminant levels can change over time. You should also test your well:
What should I do if contaminants are detected?
The Hans Premium Water appliance removes the following contaminants:
Contaminant | NSF/ANSI 58 Testing Standard | Concentration Tested | HANS™ Premium Water Results | Reduction of Up To |
---|---|---|---|---|
Hardness | <187 ppm (11 gpg) | 600 ppm (35 gpg) | <1 ppm | 99.9% |
TDS | <187 ppm | 785 ppm | 40 ppm | 94.9% |
Lead | <10 ppb | 139 ppb | <1 ppb | 99.3% |
Fluoride | <1.5 ppm | 7.54 ppm | 0.8 ppm | 89.4% |
Iron (ferric and ferrous) | <0.3 ppm | 3.46 ppm | .018 ppm | 99.5% |
PFOA & PFOS | 70 ppt | 25,000 ppt | 7 ppt | 99.9% |
Arsenic (A3 and A5) | <10 ppb | 52.4 ppb | <1 ppb | 98.1% |
Nitrate | <10 ppm | 27.9 ppm | 0.9 ppm | 96.8% |
Nitrite | <1 ppm | 3.3 ppm | 0.2 ppm | 93.9% |
Chromium 6+ | <100 ppb | 304 ppb | <1 ppb | 99.7% |
*Chloroform surrogate test includes the following chemicals: alachlor, atrazine, benzene, carbofuran, carbon tetrachloride, chloropicrin, dibromochloropropane, o-dichlorobenzene, p-dichlorobenzene, 1,2-dichloroethane, trans-1,2-dichloroethylene, 1,2-dichloropropane, cis-1,3-dichloropropylene, dinoseb, endrin, ethylbenzene, ethylene dibromide, haloacetonitriles, bromochloroacetonitrile, dibromoacetonitrile,
dichloroacetonitrile, trichloroacetonitrile, haloketones, 1,1-dichloro-2-propanone 1,1,1-trichloro-2-propanone, heptachlor, heptachlor epoxide, hexachlorobutadiene, hexachlorocyclopentadiene, lindane, methoxychlor, pentachlorophenol, simazine, styrene, 1,1,2,2-tetrachloroethane, tetrachloroethylene, toluene 1, 2,4,5-TP, tribromoacetic acid, 1,2,4-trichlorobenzene, 1,1,1-trichloroethane, 1,1,2-trichloroethane, trichloroethylene, trihalomethanes, chloroform, bromoform, bromodichloromethane, chlorodibromomethane, and xylenes.
The HANS™ Premium Water Appliance purifies your water ….
In addition to purifying your water to better-than-bottled-water quality from every tap in your home, a HANS™ unit will render your water softener useless without the hassle, cost, and negative environmental impact of salt, which leads to brine discharge back into your septic system, discharged underground into a drywell, or piped out of the building to the ground surface.
Where can I find additional resources?
[hpw]
* All health risk information provided in the above contaminant lookup utility is provided by the Environmental Working Group. More information can be found at EWG.org.
Cookie | Duration | Description |
---|---|---|
cookielawinfo-checkbox-analytics | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics". |
cookielawinfo-checkbox-functional | 11 months | The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". |
cookielawinfo-checkbox-necessary | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary". |
cookielawinfo-checkbox-others | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other. |
cookielawinfo-checkbox-performance | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance". |
viewed_cookie_policy | 11 months | The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data. |